WebSPRT (Standard Platinum Resistance Thermometer), Model 909 Working S.P.R.T.s -200°C to 662°C (572°F) Wide Operating Range 3 Probe Lengths Calibration Certificate Proven Design Nominal Diameter 7.5mm Model 909 SPRT Datasheet Silver Point Thermometer, Model … WebThe following 5 are the most commonly used thermometers in a calibration laboratory. 1. SPRT: Standard platinum resistance thermometers (SPRT’s) are the most accurate reference thermometer and are used in defining the I TS 90 (International Temperature Scale) from approximately -259 to 962 degrees C. The SPRT sensing
Sprt thermometer
Did you know?
WebDO anneal the thermometer at 480°C for the 5680 and 5682, and at 661°C for the 5699 when it has been subjected to mechanical or temper- ature shock. Page 16 5680/5682/5689 SPRT User’s Guide Model 5699 only 11. DO anneal the SPRT after delivery or when using at a temperature higher than 600°C. 12. Web17 Apr 2024 · Standard Platinum Resistance Thermometer (SPRT) sensors are highly accurate instruments for realizing the ITS-90 temperature scale between fixed points. They’re made from very pure (α = 3,926 x 10 -3 °C -1 ) platinum and the wire support is …
WebTHE STANDARD PLATINUM RESISTANCE THERMOMETER . by Henry E. Sostmann . ABSTRACT . The Standard Platinum Resistance Thermometer, acronym SPRT, is the stipulated interpolation instrument for realizing the International Temperature Scale of … Web4 Feb 2024 · Calorimetric biochemical measurements offer various advantages such as low waste, low cost, low sample consumption, short operating time, and labor-savings. Multichannel calorimeters can enhance the possibility of performing higher-throughput biochemical measurements. An enthalpy sensor (ES) array is a key device in multichannel …
WebTheInternationalPracticalTemperatureScaleof1968(IPTS68) isbasedonanumberofdefiningfixedpoints,andthestandard platinumresistancethermometer(SPRT) isusedasan interpolationinstrxmentbetweenthesefixedpoints. From0*C … WebPlatinum Resistance Thermometer (SPRT) Calibration Laboratory of the NIST Thermometry Group realizes the ITS-90 from the argon triple point (Ar TP, –189.3442 °C) to the silver freezing point (Ag FP, 961.78 °C) for the calibration of SPRTs.
WebThis is a report to the Consultative Committee for Thermometry (CCT) on the key comparison 9 of Standard Platinum Resistance Thermometer (SPRT) calibration on the International Temperature Scale of 1990 (ITS-90) [1] from 83.8058 K (the Ar triple point) to 692.677 K (the Zn freezing point). The comparison followed a collapsed star protocol, …
WebStandard Platinum Resistance Thermometers. Choosing the right standard platinum resistance thermometer (SPRT) as your primary standard may be the most critical purchase decision in your lab. Fluke Calibration has one of only a few active SPRT design groups in … Achieving 0.25 mK Uncertainty with an Integrated-Circuit Resistance … 5624 Platinum Resistance Thermometer to 1000 °C » 5626, 5628 Secondary … Fluke Calibration provides high-quality secondary platinum resistance … spa day for 15 year oldsWebModel 935-14-77 Standard Platinum Resistance Thermometer. Temperature range -50°C to 670°C. Model 935-14-77 SPRT, is the metallic sheathed version of the Model 909, the workhorse of calibration laboratories all over the world. The resistance element is of pure platinum, coiled and mounted in a strain free construction. spa day derbyshire for twoWeb1. อุณหภูมิ Resistance thermometer In-house method : (SPRT, Semi PRT, PRT, IPRT) WI.CP.04 by comparison -196 °C 0.040 °C with thermometer -80 °C to < 0 °C 0.025 °C standard 0 °C to 250 °C 0.020 °C > 250 °C to 400 °C 0.025 °C > 400 °C t 660 °C 0.050 °C Temperature indicator with In-house method : teams up 2-0Web11 Apr 2024 · A comparable procedure was used at CEM, where a set of six long-stem SPRTs were used (Table 2).Thermometers were calibrated at the TPW, TP Hg, MP Ga and FP In with the uncertainties (k=1) of : ± 0.22 mK, ± 0.25 mK, ± 0.24 mK and ± 0.50 mK respectively.These thermometers were set up in a Hart Scientific 7381 stirred alcohol … teams up arrives to collect binWebThe AM1880 Standard Platinum Resistance Thermometer (SPRT) interpolates temperature in the range from -200°C to 670°C on the International Temperature Scale of 1990 (ITS-90). It is designed as a primary or secondary standard thermometer, which can be used to calibrate other thermometers and to measure temperature precisely in primary and ... spa day for 2 cambridgeshireWebAM1880 Standard Platinum Resistance Thermometers (SPRT) interpolates temperature in the range from -200°C to 670°C on the International Temperature Scale of 1990 (ITS-90). It is designed as a primary or secondary standard thermometer to calibrate other … spa day for 2 hertfordshireWebThe following uncertainties (k=1) contribute to the total uncertainty (k=2) of the calibration of the LiG thermometers: the test (LiG) and reference (SPRT) thermometer measurement systems, the comparison baths, the ice MP, the reference SPRT, and the repeatability of the LiG thermometer. The uncertainty components described below and given in ... teams unterschied kanal team